RB2 series Redundant Power Supply

(Model: RB2 Series)

Models

  • RB2-G400VP for 400W
  • RB2-G460VP for 460W
  • RB2-G500VP for 500W
  • RB2-G550VP for 550W

Input Characteristic

  • Input connector: The input connector shall be an IEC60320 C14 inlet, rated for 15A/250Vac
  • Input Voltage and Frequency:
MinimumNominalMaximumMeasure
90100 ~ 240264Vac
4750 ~ 6063Hz
  • Input Current and Inrush Current
Input VoltageMax. Input CurrentInrush Current
115 Vac8.5 A30 A
230 Vac4 A60 A
  • Power Factor: The minimum power factor shall be 0.9 with 50% load and input 230Vac/50Hz
  • DC Output Characteristic
Output VoltageMin. CurrentMax. CurrentRegulationRipple & Noise
+3.3 V1 A24A/24A/25A/25A+/-5%50mV
+5 V1 A24A/24A/25A/25A+/-5%50mV
+12 V1 A33A/38A/41A/45A+/-5%120mV
-12 V0 A0.8A+/-5%120mV
+5 VSB0.1 A2.5A/2.5A/3.5A/3.5A+/-5%50mV
  • Efficiency: The power efficiency shall meet 80Plus GOLD
  • Hold-up Time: The output voltages stay in regulation at least 18ms with 80% load after loss of AC input
  • Rise Time: The output voltages rise from 10% to 90% with full load, and shall be in 5ms to 70ms