Home News Product Contact Us Inquiry Site Map
|
- SS-2U40ES for 400W output
- SS-2U50ES for 500W output
- SS-2U60EL for 600W output
- SS-2U70EL for 700W output
- Input connector: The input connector shall be an IEC60320 C14 inlet, rated for 15A/250Vac
- Input Voltage and Frequency:
Minimum |
Nominal |
Maximum |
Measure |
90 |
100 ~ 240 |
264 |
Vac |
47 |
50 ~ 60 |
63 |
Hz |
- Input Current and Inrush Current:
Input Voltage |
Max. Input Current |
Inrush Current |
115Vac |
8A/8A/10A/10A |
25A |
230Vac |
4A/4A/5A/5A |
50A |
- Power Factor: The minimum power factor shall be 0.95 with full load and input 230Vac/50Hz
- DC Output Characteristic:
Output Voltage |
Min. Current |
Max. Current |
Regulation |
Ripple & Noise |
+3.3V |
1A |
25A |
+/-5% |
50mV |
+5V |
1A |
25A |
+/-5% |
50mV |
+12V |
1A |
32A/40A/48A/56A |
+/-5% |
120mV |
-12V |
0A |
0.8A |
+/-5% |
120mV |
+5VSB |
0.1A |
3.5A |
+/-5% |
50mV |
- Efficiency: The minimum efficiency of power supply is 80% with full load and 115Vac/60Hz input
- Hold up Time: The output voltages stay in regulation at least 16ms with 100% load after loss of AC input